TM 9-2350-311 -20-1 CONTINUED FROM STEP H I n Repair or replace lead 27 of bulkhead- to-portable instrument panel wiring harness (para 8-49). Repair or replace lead 27 of portable instrument panel wiring harness (para 8-57). CONTINUED FROM STEP G 1. Reconnect lead 27 to circuit breaker output. 2 Disconnect lead 10 from circuit breaker . input. 3. Place red lead of multimeter in lead 10 and black lead to ground. 4. Turn MASTER switch ON and check for voltage. 5. Turn MASTER switch OFF. Is voltage present? Troubleshoot master relay circuit (para 3-3b). I Replace circuit breaker (para 8-33, M109A2/M109A3; 8-34, M109A4/M109A5). END OF TASK 3-195