TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 273 of 1275
CONTINUED FROM STEP F 1 1. Reconnect lead 82 of master relay-to- driver’s bulkhead lead assembly to master relay. 2. Disconnect master relay-to-driver’s bulkhead lead assembly from driver's bulkhead. 3. Place red lead of multimeter in lead 82 and black lead to ground. 4. Turn MASTER switch ON, and check for voltage. Is voltage present? I Repair or replace lead 10 of power lead wiring harness (para 8-56). Repair or replace lead 82 of master relay-to-driver’s bulkhead lead assembly (para 8-82). 3-173 TM 9-2350-311-20-1