TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download

Page 257 of 1275

TM 9-2350-311-20-1 CONTINUED FROM STEP A I B 1. Disconnect lead 40A from BATTERY indicator. 2. Place red lead of multimeter in lead 40A and black lead to ground. 3. Turn MASTER switch ON and check for voltage. 4. Turn MASTER switch OFF. Is voltage present? I Replace BATTERY indicator (para 8- 17). m I . 3. 4. 5. 1. 2. Reconnect lead 40A to BATTERY indicator. Disconnect lead 27 from circuit breaker output. Place red lead of multimeter in circuit breaker output and black lead to ground. Turn MASTER switch ON and check for voltage. Turn MASTER switch OFF. Is voltage present? I Go to step E. I I CONTINUED ON NEXT PAGE 3-157