TM9-2350-311-20-1 CONTINUED FROM STEP E T 1. Remove powerplant (para 4-5). 2. Connect special equipment for operation of powerplant out of vehicle (para 4-5). 3. Place red lead of multimeter on lead 14B at starter solenoid and black lead to ground. 4. Turn MASTER switch ON, push STARTER switch, and check for voltage. 5. Turn MASTER switch OFF. Is voltage present? Repair or replace lead 14B of powerplant wiring harness (para 8-44). 1. Place red lead of multimeter on lead 6A at I starter solenoid and black lead on ground (lead 5A). 2. Turn MASTER switch ON and check for voltage. 3. Turn MASTER switch OFF. I Is voltage present? I Replace starter motor (para 8-14). I I I I I (para 8-84). Repair or replace leads 5A and 6A of starter-to-engine electrical disconnect END OF TASK 3-51