TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 135 of 1275
TM 9-2350-311-20-1 CONTINUED FROM STEP I 1. 2. 3. 4. 5. Reconnect lead 14 to output side of neutral safety switch. Disconnect lead 14 from input side of neutral safety switch. Place red lead of multimeter in lead 14 and black lead to ground. Turn MASTER switch ON, push STARTER switch, and check for voltage. Turn MASTER switch OFF. Is voltage present? Replace neutral safety switch (para 8-15). 1. Reconnect lead 14 to input side of neutral 2. 3. 4. 5. safety switch. Disconnect lead 14 from output side of STARTER switch. Place red lead of multimeter in STARTER switch and black lead to ground. Turn MASTER switch ON, push STARTER switch and check for voltage. Turn MASTER switch OFF. 1 Is voltage present? Repair or replace lead 14 of bulkhead- to-portable instrument panel wiring I harness (para 8-49). I 1 CONTINUED ON NEXT PAGE 3-35