TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 1207 of 1275
TM 9-350-311-20-1 Problem is either due to weak batteries, or tight engine. Go to NG 23 (Figure 3, sheet 10). Short circuit is in starter circuit. Go to paragraph 3-3 to check. If multimeter is needed, use VTM. Go to step 4, Figure 3, sheet 6. Try to crank engine. If GO is still displayed after cranking, starter is not being energized. Go to step 4, Figure 3, sheet 6. Check battery connections and repeat step 2, Figure 3, sheet 3. After completing repair, rerun GO CHAIN tests to verify problem has been fixed and that no other problems exist. Start at GO 2 (Figure 2, sheet 8) if VTM is already connected. Otherwise start at GO 1 (Figure 2. sheet 1). Figure 3 Sheet 4 of 36 I-30 NOTE Go to step 3, Figure 3, sheet 5.