TM-9-2350-311-20-1 Maintenance Manual for Volume 1 M109 Hull Download
Page 1186 of 1275
TM9-2350-311-20-1 GO 1 VTM CONNECTIONS AND CHECKOUT — CONTINUED BATTERIES. . - Set power switch to PULL OFF. - Connect power cable W5 to known good batteries. - PUSH ON VTM power switch. Does VTM display .8.8.8.8 and then change to----? - Check vehicle electrolyte level. - Clean battery terminals. - Check battery specific gravity, as applicable (para 8-28). - Charge batteries if necessary. - Return to step 1, Figure 2, sheet 2. - Refer to TM 9-4910-571-12&P for fault isolation of cable W5. - If cable is bad, replace it. - If cable is good, STE/ICE-R is bad. - Replace STE/ICE-R. Figure 2, Sheet 3 of 20 I-9 CONNECT TO KNOWN GOOD