12-1 AIR PURIFIER — CONTINUED b. Removal 1 2 3 4 5 Disconnect two hoses (3 and 6) from air purifier manifold (4). Disconnect electrical connector (8). Remove two screws (9 and 10), two Iockwashers (11 and 12), and ground lead (13) from air purifier (2) and dome light (14). Install Iockwashers and screws. Release strap (15) on air purifier bracket (16). Remove air purifier (2) from bracket (16). 12-4 TM9-2350-311-20-1