TM 9-2350-311-10 3-7 FIRE CONTROL ALINEMENT TESTS AND MEASUREMENTS — CONTINUED 3-7.3 Leveling Gun Trunnions — Continued a. Plumbline Method-Continued 14 Set off 100 mils on M15 elevation quadrant (12) and elevate the cannon tube (6) manually until the elevation bubble (15) centers. 3-90