TM-9-2350-311-10 M109 Operator's Manual for M109A2, M109A3, M109A4 and M109A5 Download

Page 422 of 775

TM 9--2350--311--10 3--22 Change 6 3--5 HULL MAINTENANCE PROCEDURES — CONTINUED 3--5.4 Maintenance of Air Cleaner — Continued b. Cleaning WARNING Wear eye protection. Particles released from air cleaner filters during cleaning could injure eyes. Air cleaner filters will become contaminated when operating in an NBC environment. Contaminated air cleaner filters must be handled and disposed of in accordance with FM 3--3 and FM 3--4. 1 Clean air cleaner filters (8) with compressed air. (Emergency clean by tapping bottom or sides against flat surface. Do not strike open or sealing edge of air cleaner filters.) 2 Clean air cleaner filter compartments (9). c. Installation 1 Install air cleaner filters (8) by alining with outlet gaskets to assure proper sealing and secure locking levers (7). 2 Slide right and left access doors (3 and 5) on air cleaner and secure by pulling locking latches (4 and 6) down and then up. 3 Install hull ammunition rack (1) and secure with two quick-release pins (2). 4 Reset air cleaner indicator (10) by pushing up on reset button (located on bottom of cylinder). 5 Start engine. If indicator gage reads 25 in. H 2 O or greater, notify unit maintenance.