TM-9-2350-311-10 M109 Operator's Manual for M109A2, M109A3, M109A4 and M109A5 Download
Page 364 of 775
TM 9-2350-311-10 2–17 OPERATING AUXILIARY EQUIPMENT — CONTINUED 2-17.6 NBC Equipment (M109A4/M109A5 Howitzers) — Continued b. Operation of Hull NBC Equipment — Continued NOTE Illustration for steps 4 and 5 shows driver’s station only, but procedures apply to both cannoneer no. 2’s and the driver’s station. 4 Pull orifice connector (6) from bracket (7) and connect to M25A1 mask (not shown). NOTE Indicator light on M3 electrical air heater will go off and on during operation as heating element adjusts to control air temperature. 5 Turn THERMOSTAT control knob (8) on M3 electrical air heater (9) to ON and incandescent lamp (10) will illuminate. Adjust air temperature for comfort. 2-264