TM-9-2350-311-10 M109 Operator's Manual for M109A2, M109A3, M109A4 and M109A5 Download
Page 224 of 775
TM 9--2350--311--10 Change 6 2--125 2--10 OPERATING PROCEDURES — CONTINUED 2--10.7 Operating Miscellaneous Items — Continued b. Engine Air Cleaner 1 For summer position, when temperatures are over 40° F (4° C), leave locking handles (3) in holders. 2 For winter position, when temperatures are below 25° F (--4° C), raise locking handles (3) and fasten on hooks (4). 3 For intermediate temperatures between 25 to 40° F (--4 to 4° C), start engine with locking handles (3) in winter position. When engine reaches operating temperature, place locking handles in summer position. 4 An air cleaner indicator (5) is located alongside the left air cleaner. It reads less than 25 in. H 2 O when air cleaner is operating properly. When airflow is restricted, the gage reads 25 in. H 2 O or greater indicating that the air cleaner element should be serviced (para 3--5.4). The air cleaner indicator gage locks into position every 5 in. H 2 O. A reset button on the bottom of the air cleaner indicator gage must be pushed to zero the gage. NOTE Air cleaner shown in winter position.