TM 9--2350--311--10 2--51 Table 2--1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M109 SELF-PROPELLED HOWITZER — CONTINUED Location Item No. Not Fully Mission Capable If: Crewmember Procedure Item to Check/ Service Interval 30 Before M146 Telescope Mount (Cont) ASSISTANT GUNNER NOTE Tapered pin (king pin) and cable assembly recep- tacle should be installed on M146 telescope mount whether or not M118A2/M118A3 elbow telescope is installed. b. Check cable assembly receptacle (4) of cable assembly (5) for damage. 4 5 TAPERED PIN (KING PIN)