TM-9-2350-311-10 M109 Operator's Manual for M109A2, M109A3, M109A4 and M109A5 Download

Page 129 of 775

TM 9–2350–311–10 Change 3 2–43 Table 2–1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M109 SELF-PROPELLED HOWITZER — CONTINUED Location Item No. Not Fully Mission Capable If: Crewmember Procedure Item to Check/ Service Interval 25 Before Recuperator Assembly CHIEF OF SECTION WARNING Do not attempt to remove drain plug complete- ly. Hydraulic fluid in recuperator assembly is under high pressure and could cause injury. CAUTION If drain plug is loosened for draining hydraulic fluid, check for leaks after tightening cover. To prevent damage to gasket or cover, loosen cap screws to stop pins before rotating cover. Before firing, check pins (1) in recuperator assem- bly (2) from outside of vehicle, and check pins (3) in recuperator head (4) from inside vehicle. Pins must extend from 1/4 to 3/4 inch (6.4 to 19.05 mm). If pins extend beyond 3/4 inch (19.05 mm), fill recup- erator assembly (2) by removing valve cap (5) from valve (6). Fill M3 oil gun (item 17, Table 2–1) and add hydraulic fluid (item 20, Appx D) until pins ex- tend 1/4 inch (6.4 mm). If pins extend less than 1/4 inch (6.4 mm), loosen drain plug (7) and drain hy- draulic fluid until pins extend 1/4 inch (6.4 mm). Pins (1 and 3) cannot be brought into spe- cified range. 1 2 3 4 5 6 CAP SCREW COVER 5 6 7