TM-9-1290-365-24&P Technical and Parts Manual for Paladin Muzzle Velocity System M93 Upgraded Download
Page 68 of 334
ARMY TM 9-1290-365-24&P 3.3.7 Fault Isolation Table. Refer to Figures 3-7 and 3-8. Table 3-9. Fault Isolation Table Fault at Para. 3.3.6.2 step Fault Connectors Pin and Wiring Repair Procedure f. J2/A - P6/A Check and replace J2 or P6 connector g. J2B - P6B Check and replace J2 or P6 connector h. J2/C - J3/C Check and replace J2 or J3 connector i. J3/E - P3/E Check and replace J3 or P3 connector j. J3/F - P3/ F Check and replace J3 or P3 connector m. J2/A,B or P6/A,B Check and replace J2 or P6 connector n. J1/A,B or P6/A,B Check and replace J2 or P6 connector o. J2/C or J3/C or P3/C Only C1 on. Check and replace P3. Only C2 ON. Check and replace J3 both are off. Check and replace J2. P. J3/E,F P3/E,F 1553 Stub (see para. 3.3.8) Check and replace J3, P3 or 1553 Stub (see para. 3.3.8) q. J3/E,F P3/E,F 1553 Stub (see para. 3.3.8) Check and replace J3, P3 or 1553 Stub (see para. 3.3.8) r. J2/A,B,E,F,C Check and replace J2 connector t. J2/E,F 1553 Stub T1 (see para. 3.3.8) Check and replace J2 connector or 1553 Stub T1 (see para. 3.3.8) u. J3/E,F 1553 Stub T1 or R1, R2 (see para. 3.3.8) Check and replace J3, P3 or 1553 Stub T1, R1, or R2 (see para. 3.3.8) w. 1553 Stub T1 (see para. 3.3.8) Check and replace 1553 Stub T1 (see para. 3.3.8) 3-20