TM-9-1290-365-24&P Technical and Parts Manual for Paladin Muzzle Velocity System M93 Upgraded Download

Page 65 of 334

ARMY TM 9-1290-365-24&P 3.3.6.2 TEST PROCEDURE . Refer to Figures 3-5, 3-6, 3-7, and 3-8. Check cable as follows: a. Verify Tester is OFF b. Set DMM to resistance mode. c. Measure self-resistance of DMM. d. Make sure to subtract DMM self-resistance from result. e. Connect DMM between TP5 and TP6. f. Set S1 to position A. Verify resistance is less than 1.0 . g. Set S1 to position B. Verify resistance is less than 1.0 . h. Set S1 to Position C. Verify resistance is less than 1.0 . i. Set S1 to position E. Verify resistance is less than 1.0 . j. Set S1 to position F Verify resistance is less than 1.0 . k. Set S1 to position A. I. Turn power supply on. Turn Tester on. m. Verify only LED A is on. n. Set S1 to position B. Verify only LED B is on. o. Set S1 to position C. Verify only LEDs C1 and C2 are on. p. Set S1 to position E. Verify only LEDs E and F are on. NOTE Oscilloscope and function generator must NOT both be grounded at their 115V power input or the LEDs of E and F remain “ON” in “IDLE” position. q. Set S1 to position F Verify only LEDs E and F are on. r. Set S1 to position idle. Verify no LED is on. s. Turn off power supply. t. Measure resistance between TP6 and TP5. Verify resistance measured is 2±1.25 . u. Measure resistance between TP4 and TP2. Verify resistance measured is 114.5±1.5 . v. Set function generator to square wave of 1 MHz and 20±0.5 Vp-p amplitude. w. Measure signal with scope. Verify square wave amplitude is 28 ± 0.75 Vp-p and frequency is 1 MHz ± 1 Hz. x. End of test. 3-17