ARMY TM 9-1290-365-24&P 3.1.5 Refinish of Painted Surfaces. WARNING CARC paint is a carcinogenic material and must be used carefully. CAUTION DO NOT PAINT TRANSCEIVER RADOME. Repair Transceiver Assy painted surfaces in accordance with TM 43-0139 using forest green color CARC IAW FED-STD-595. 3.1.6 Replacement of Identification Plates. Replace damaged plates as follows: a. Remove plate by peeling. b. Be sure plate installation area is clean of old bonding residue. Refer to para. 3.1.3 for cleaning instructions. c. Remove protective covering from back of plate and firmly press plate into place. 3.1.7 Cable Testing. Cable assembly testing consists of performing continuity checks. Each cable shall be tested for compliance with its individual wiring diagram. Refer to appropriate sections in Chapter 3 for cable testing and repair procedures. 3.1.8 Troubleshooting. Troubleshooting of the M93 MVS is limited to the interface between the MVS and AFCS. Troubleshoot IAW Table 3-3. 3.1.9 Shipping Instructions for items not repairable at field level: a. Fill out DA 2407 and/or DA 2404 to describe defects with item and where the items need to be returned to. If serialized, include serial number of unit. b. Address for Shipping: Borish Manufacturing Corp. 4511 East Paris SE Grand Rapids, MI 49512 DODAC: CMASD8 RIC: CCA c. Send one copy of DA Form 2404 and 2407 to the above address and one copy to the following address: TACOM-RI ATTN: AMSTA-LC-CFTC Rock Island Arsenal Rock Island, IL 61299-7630 Change 1 3-5