TM-9-1290-365-24&P Technical and Parts Manual for Paladin Muzzle Velocity System M93 Upgraded Download

Page 284 of 334

ARMY TM 9-1290-365-24&P Table D-24. Standard Measurement Equipment Nomenclature Part/Spec. No. Figure Microwave Frequency Counter EIP Model 535 C-11, 22 Function Generator Wavetek, Model 178 C-11, 23 Oscilloscope Hewlett Packard, Model 1070B C-11, 17 Power Supply, DC (0-40V, 5A) Lambda, LLS-9040 C-11, 24 Power Supply, DC (0-40V, 1 A) 2 each Lambda, LLS-5040 C-11, 25 Coaxial Cable, BNC, Male-To—Male, 50 (2 (3) Local Manufacture N/A RMS Voltmeter Hewlett-Packard, Model 3400A C-11, 26 Power Meter Hewlett-Packard, Model 432B C-11, 27 Thermistor Mount Hewlett-Packard, Model 84788 C-11, 28 D.9.2.3.2 Microwave Measurement Equipment. D.9.2.3.2.l Connection. The microwave measurement equipment (MME) is listed in Table D-25. and should be connected as described in Figure D-40. prior to testing of the transceiver assembly. It should be calibrated for overall insertion loss for power and sensitivity measurements. Table D-25. Microwave Measurement Equipment Nomenclature Part/Spec. No. Figure Coaxial Cable, SMA, Male-To-Male, 50 ohm (3) Local Manufacture N/A Coaxial Cable, SMC Female/BNC Male, 50(2 Local Manufacture N/A WR9O/SMA Female Adapter (4) Midwest Microwave, 3625 C-11,42 Pin Switch General Microwave, Model 9114 C-11,42 Phase Shifter Midisco, Model MDC1 089-1 C-11,42 Fixed Coaxial Attenuator, 20dB Weinschel, Model 4M C—11, 30 Variable Waveguide Attenuator Hewlett-Packard, Model X382A C-11,42 Waveguide Directional Coupler Hewlett-Packard, Model X752D C-11,42 Termination, 50 ohm Midwest Microwave, 2444M C11,42 SMA Female/SMA Female Adapter Midwest Microwave, 2595 C-11,31 N-Type Female/SMA Male Adapter Midwest Microwave, 2682 C-11,42 D-114