TM-9-1290-365-24&P Technical and Parts Manual for Paladin Muzzle Velocity System M93 Upgraded Download

Page 246 of 334

ARMY TM 9-1290-365-24&P D.6.1 1.4.5 Deenergize all test equipment. End of test Table D-14. Power Supply Module Adjustment Data Sheet SER NO. D.6.11.4.2d. SERIAL NO. RF MODULE DESIRED VOLTAGE V= ____________ D.6.11.4.2e. OUTPUT VOLTAGEl 0+10 Vdc________________ D.6.11.4.3c. MEASURED RESISTANCE RM______________ D.6.11.4.3d. CHOSEN RESISTORS R1 6 ______________________ R1 7 ______________________ D.6.11.4.4c. MEASURED Vout = _______________ Date: ____________________________ Tested by: ____________________________ Inspected by: ____________________________ D.6.1 2 Troubleshooting. This paragraph contains the troubleshooting procedures for UUT failures detected during testing. It is arranged in the sequence of test steps, and provides information on addi- tional test steps required for the malfunction isolation. Refer to FO-4 for schematic diagram. Refer to D-25 for components location. CAUTION The power supply module contains components subject to damage by electros- tatic discharge. Use approved grounding procedures before touching, removing, or inserting CCA. CAUTION Deenergize all external power supplies and other test equipment when disassembling or reassembling the UUT. NOTE In all troubleshooting procedures, when additional disassembly or reassembly is required, refer to the appropriate disassembly (D.6.5) or reassembly (D.6.10) procedure. After completion of troubleshooting and repair, perform the complete test procedure from the start. In all troubleshooting procedures the test equipment and voltage settings shall be lAW the test procedure. Voltages shall be measured to their respective grounds. D-76 Change 1