TM-9-1290-365-24&P Technical and Parts Manual for Paladin Muzzle Velocity System M93 Upgraded Download
Page 214 of 334
ARMY TM 9-1290-365-24&P D.4.1 2.3.6 Remote Control Test. Refer to para. D.4.12.3 3.8 for troubleshooting procedures. NOTE During the test, the message “AAAA Stay Alive” may appear several times. a. Turn on the 1553 Simulator. b. Using the mouse, on the PC choose “Start” from the EVENT menu. c. Verify the following message on screen: “AAAA BIT FAILURE FALSE YYY.Y Ver X.X” “AAAA Stay alive” where: AAAA = message sequence no. YYY.Y = 3955 m/sec. X.X = last version no. d. Choose “BIT Status” from the EVENT menu. e. Verify the following message on screen: “AAAA BIT FAILURE FALSE YYY.Y Ver. X.X” Where AAAA = message sequence no. YYY.Y = 3955 m/sec. X.X = last version no. f. Set velocity range from the EVENT menu to: 100 m/s min, 1000 m/s max. g. On the Test Doppler Simulator set EXTERNAL,INTERNAL switch to EXTERNAL position. h. Turn on function generator and set to square wave 8Vp-p, 4Vdc offset on output, 14KHz ±12.3 Hz. i. Choose “SHELL” from the EVENT menu. Press and release the ACCL. switch on the test cable. j. Verify the following message on screen: “AAAA “Velocity YYY.Y TRUE” Where: AAAA = message sequence no. YYY.Y = 199.00.5 m/sec. k. Set function generator to 50KHz ±1Hz. I. Choose “SHELL” from the EVENT menu. Press and release the ACCL. switch on the test cable. m. Verify the following message on screen: “AAA VELOCITY YYY.Y TRUE” where: AAAA = message sequence no. YYY.Y = 710.90.6. n. Choose “SHELL” from the EVENT menu. o. Tap the transceiver assembly back cover using plastic hammer to activate the acceleration switch mounted on the MVP CCA. p. Verify the following message on screen: “AAA VELOCITY YYY.Y TRUE” where: AAAA = message sequence no. YYY.Y = 710.90.6. D.4.12.3 2.3.7 Deenergize power supply. Set P.S/BAT switch on Doppler simulator to P.S. Disconnect all test equipment from transceiver. END-OF-TEST D-44