TM-9-1240-401-34&P Technical Manual for M109 Telescopes and Mounts Download
Page 79 of 344
a. Removal TM 9-1240-401-34&P 3-17. COVER ASSEMBLY MAINTENANCE INSTRUCTIONS (M118A2) This task covers: a. Removal b. Disassembly c. Repair d. Assembly e. Installation Sealing compound (Item 15, appx B) Tape (Item 20, appx B) Tool Kit, Electronic System, Repair, Field Mainte- nance (SC5180-95-CL-B29) 5180-01-168-0487 TM 9-254 TM 750-116 Adhesive (Item 2, appx B) Lockwashers (4) (Item 68, appx E) M118A2 elbow telescope removed from howitzer Preformed packing (Item 42, appx E) (TM 9-2350-311-10) 1 Remove cover assembly (1) from housing (2) by removing four machine screws (3) and four lock- washers (4). Discard Iockwashers. 2 Using tape, tag wires on wiring harness (5). 3 Remove machine screws (6 and 7) and disconnect wiring harness (5) from cover assembly (1). 3-21