TM-9-1240-401-34&P Technical Manual for M109 Telescopes and Mounts Download

Page 64 of 344

3-6 TM 9-1240-401-34&P 3-9. DIRECT SUPPORT TROUBLESHOOTING - continued MALFUNCTION TEST OR INSPECTION LOCATION CORRECTIVE ACTION 2. 3. 4. 5. 6, EYEPIECE ARM (2) DOES NOT MOVE EASILY OR REMAIN IN LOCKED POSITION. Move eyepiece arm (2) from stop to stop. a. Repair lock-release lever (ref. para 3-13). b. Replace bellows assembly (ref. para 3-13). KNOBS (3) ON WORMSHAFT ASSEMBLY BIND. Rotate knobs (3) on wormshaft assembly. Repair wormshaft assembly (ref. para 3-15). RETICLE (4) OR LEVEL VIAL (5) ARE NOT lLLUMl- NATED. Turn variable resistor knob (6). a. b. c. Replace incandescent lamp for Ml 18A2 (ref. para 3-17) for cover assembly and para 3-19 for level). Replace circuit board assembly for M118A3 (ref. para 3-18 for level). Replace variable resistor (ref. para 3-13). LEVEL (5) HAS NO BUBBLE. Observe visually. Repair level assembly, M118A2 (ref. para 3-19). Repair level assembly, M118A3 (ref. para 3-18). LENS (7) IS FOGGED OR CONDENSATION IS PRESENT. Observe visually. Purge and charge M118A2/M118A3 elbow telescope (TM 750-116).