TM-9-1240-401-34&P Technical Manual for M109 Telescopes and Mounts Download

Page 315 of 344

6-5 TM 9-1240-401-34&P Section IV. General Support Maintenance Procedures 6-10. M42 PERISCOPE MAINTENANCE INSTRUCTIONS This task covers: a. Disassembly b. Repair c. Assembly Tools Tool Kit, Electronic System, Repair, Field Main- tenance (SC5180-95-CL-B29) 5180-01-168-0487 Materials/Parts Adhesive (Item 2, appx B) Lockwashers (3) (Item 64, appx E) Lockwashers (24) (Item 65, appx E) Lockwashers (4) (Item 69, appx E) Sealing compound (Item 13, appx B) a. Disassembly 1 2 3 4 5 6 7 Remove two machine screws (1) and identification plate (2). Remove air valve cap (3), valve core (4), purging valve stem (5), and retaining strap (6) from M42 periscope. Remove purging machine screw (7). Remove two headless straight pins (8) only if nec- essary for replacement. Remove four machine screws (9), four Iockwashers (10), and two retaining plates (11). Discard Iockwashers. Remove 12 machine screws (12), 12 Iockwashers (13), and plate and mirror (14). Discard lock- washers. Remove two headless straight pins (15) only if damaged. References TM 9-254 TM 750-116 M42 periscope removed from howitzer (TM 9-2350-311-20-2)