TM-9-1240-401-34&P Technical Manual for M109 Telescopes and Mounts Download
Page 196 of 344
TM 9-1240-401-34&P I 5-15. LAMP ASSEMBLY AND RELATED PARTS (M117A2) MAINTENANCE INSTRUC- TIONS - continued I a. Removal/Disassembly - continued I 22 23 24 25 Remove two machine screws (39) and two lock- washers (40) from contact assembly (41 ). Discard lockwashers. Remove two machine screws (42), two lock- washers (43), and retaining strap (44). Discard Iockwashers. Remove contact assembly (41). Remove three machine screws (45), three lock- washers (46), and housing (47). Discard lock- washers. I b. Repair I 1 Remove corrosion, grease, and dirt from all parts. Refer to TM 9-254 for cleaning instructions. 2 Visually inspect for missing or damaged parts. 3 Repair or replace parts in accordance with author- ized parts listed in appendix D. I c. Assembly/installation I 1 2 3 4 5 Install housing (47) on upper housing (48) and se- cure with three new Iockwashers (46) and three machine screws (45). Install contact assembly (41) on upper housing (48) and secure with two new Iockwashers (40) and two machine screws (39). Install contact assembly (41) in housing (47) and secure with retaining strap (44), two new lock- washers (43), and two machine screws (42). Install two tubes (35) into holder (37) and plug (34). Install electrical lead (28) and wire (31) in holder (37) with raised brass portion facing outward. 5-22