TM-9-1240-401-34&P Technical Manual for M109 Telescopes and Mounts Download
Page 193 of 344
TM 9-1240-401-34&P 11 12 13 14 15 16 17 18 19 Install electrical lead (15) with wire and lug terminal (16) attached. Using 11/1 6 and 45/64 inch tubular spanner wrench, install threaded ring (14). Install housing (13) on M117 panoramic telescope and secure with machine screw (12). Solder three lug terminals (10) on wires (11) using solder and flux. Install three lug terminals (10) with wires (11) at- tached on housing (13) and secure with machine screw (9), new Iockwasher (8) and machine screw (7). Install access cover (6) and secure with four ma- chine screws (5). Install LED (4). Install electrical connector cover (3) and secure chain with new Iockwasher (2) and machine screw (1). NOTE Repeat steps 8 through 12, then 17 and 18 for second lamp assembly. Purge and charge optics (ref. TM 750-116). 5-19