TM 9-1240-401-34&P 4-13. M145/M145A1 TELESCOPE MOUNT MAINTENANCE INSTRUCTIONS This task covers: a. Disassembly b. Repair c. Assembly Tools Lockwashers (5) (Item 64, appx E) Lockwashers (4) (Item 65, appx E) Soldering iron (Item 24, appx F) Lockwashers (7) (Item 68, appx E) Lockwashers (2) (Item 70, appx E) Tool Kit, Electronic System, Repair, Field Mainte- Lockwashers (4) (Item 73, appx E) nance(SC5180-95-CL-B29) Oil, lubricating (Item 9, appx B) 5180-01-168-0487 Sealing compound (Item 13, appx B) Torque adapter (Item 6, appx F) Solder (Item 18, appx B) References Torque wrench (Item 36, appx F) TM 9-254 . . ment Condition Flux (Item 5, appx B) Grease (Item 6, appx B) M145/M145A1 telescope mount installed on Lockwashers (3) (Item 63, appx E) howitzer. t 1 a. Disassembly I 2 3 4 5 6 1 Remove three machine screws (1), three lock- washers (2), and plate insulator (3). Discard lock- washers. Remove three machine screws (4), three lock- washers (5), and three wires (6) with three lug ter- minals (7) and three sleeves (8) attached. Discard Iockwashers. Remove two machine screws (9), two Iockwashers (10), two wires (11) with two lug terminals (12) and two sleeves (13) attached, plate (14), and plate insulator (15). Discard Iockwashers. Remove machine screw (16), Iockwasher retaining strap (18). Discard Iockwasher. (17), and Remove two machine screws (19), disk insulator (20), and disk insulator (21). Remove machine screw (22) and nut (23) from two lug terminals (24). 4-11