TM-9-1240-400-34&P Technical Manual for M109 Telescopes and Mounts Download

Page 36 of 344

TM 9-1240-400-34&P 2-10. MAINTENANCE OF M115 PANORAMIC TE DISASSEMBLY 1 Remove three setscrews (1) and head assembly (2) from body assembly (3). 2 Remove two screws (4) and identification plate (5). 3 Remove and discard preformed packing (6). 4 Remove three setscrews (7) and setscrew (8) from body assembly (3). 5 Remove two screws (9) and stop (10). 6 Turn collar (11) counterclockwise to disengage body (3) from elbow assembly (12). 7 Remove spring tension washer (13) and positive clutch half (14) from body assembly (3). 8 Remove preformed packing (15) from groove in elbow assembly (12). Discard preformed packing. CLEANING Clean all parts per TM 9-254. REPAIR 1 Head assembly is a repairable assembly; refer to page 2-22. 2 Body assembly is a repairable assembly; refer to page 2-28. 3 Elbow assembly is a repairable assembly; refer to page 2-50. Repair is by replacement of authorized parts as required. Refer to appendix B. 2-20