TM 9–1200–215–34&P 2–21 2–17. TCIM CCA MAINTENANCE INSTRUCTIONS CONTINUED a. REMOVAL CONTINUED CAUTION The connector panel assembly is attached by cables to internal components of ACU and cannot be moved very far from housing without putting strain on those cables. Exercise caution when removing bottom cover from ACU housing. Failure to comply may result in damage to equipment. 5. Remove ACU connector panel (6) by removing 16 screws (7) and 16 flat washers (8). Lift connector panel off housing. CAUTION The EMI shielding gasket is vital to this piece of equipment and is easily damaged. Handle with care when removing or replacing it. Failure to comply may result in damage to equipment. 6. Inspect EMI shielding gasket (9) in groove in housing (10) for cuts, nicks, or signs of stretching. Discard EMI shielding gasket if unserviceable. 7. Loosen two captive screws (11) securing card edge connector (12) to side of TCIM CCA. 8. Gently remove TCIM CCA (2) from backplane connector J5 (13) in ACU housing and place CCA in ESD protective bag. 6 7 8 9 2 11 12 13 10