TM-9-1200-215-34&P Technical Manual for M109 Automatic Fire Control System (AFCS) Download

Page 50 of 266

TM 9–1200–215–34&P 2–15 2–14. CCA ST ABILIZER BRACKET MAINTENANCE INSTRUCTIONS CONTINUED b. INSTALLATION CAUTION ESD SENSITIVE The ACU contains ESD sensitive components. Wear a protective ESD wrist strap whenever handling components. Failure to comply may result in damage to equipment. 1. Attach ESD grounding strap to wrist and ground to ensure ESD protection. NOTE The two stabilizer brackets are different lengths. The longer bracket should be positioned at middle of ACU. 2. Place CCA stabilizer bracket (1 and 2) into position in ACU and align holes. 3. Insert four screws (3), four new lockwashers (4), and four flat washers (5) securing each stabilizer bracket into ACU. Torque screws to 20 in.–lb (2.3 NSm). 4. Install top panel in accordance with procedure outlined in paragraph 2–13. 1 5 4 3 2 5 4 3