TM-9-1200-215-34&P Technical Manual for M109 Automatic Fire Control System (AFCS) Download

Page 49 of 266

TM 9–1200–215–34&P 2–14 2–14. CCA ST ABILIZER BRACKET MAINTENANCE INSTRUCTIONS DESCRIPTION This task covers: a. Removal b. Installation INITIAL SETUP Tools: Tool Kits, JTK–17LAL, TK–101/G, or TK–105/G (items 34, 35, & 36, Appendix E) Torque Wrench, 0–75 in.–lb (item 40, Appendix E) Socket Wrench, Sockethead Screw, 9/64” (item 67, Appendix E) Materials/Parts: Lockwasher (item 1, Appendix F) Equipment Conditions: Top panel removed; if not, remove top panel in ac- cordance with procedure in paragraph 2–13 Personnel Required: One MOS 35Y a. REMOVAL CAUTION ESD SENSITIVE The ACU contains ESD sensitive components. Wear a protective ESD wrist strap whenever handling components. Failure to comply may result in damage to equipment. 1. Attach ESD grounding strap to wrist and ground to ensure ESD protection. 2. Remove CCA stabilizer brackets (1 and 2) by removing four screws (3), four lockwashers (4), and four flat washers (5) securing each stabilizer bracket. Lift stabilizer bracket from ACU. Discard lockwashers. 1 5 4 3 2 5 4 3