TM-9-1200-215-34&P Technical Manual for M109 Automatic Fire Control System (AFCS) Download

Page 126 of 266

TM 9–1200–215–34&P 4–12 4–15. TOP COVER ASSEMBL Y AND BOTTOM COVER, RFI/EMI CONTACT STRIP CONTINUED b. INSTALLATION CAUTION ESD SENSITIVE The PDIU contains ESD sensitive components. Wear a protective ESD wrist strap whenever handling components. Failure to comply may result in damage to equipment. Damage to RFI/EMI contact strip may occur. Do not slide cover off of housing. Pick cover straight up. 1. Attach ESD grounding strap to wrist and ground to ensure ESD protection. 2. Remove backing from adhesive on replacement RFI/EMI contact strip (1). 3. Press strip (1) in place on top/bottom cover (2). 4. Install top/bottom cover (2) in accordance with procedure outlined in paragraph 4–13. 2 2 1 1 CONTACT FINGER EDGE CONTACT FINGER EDGE