TM-9-1200-215-34&P Technical Manual for M109 Automatic Fire Control System (AFCS) Download
Page 107 of 266
TM 9–1200–215–34&P 3–16 3–16. HANDLE MAINTENANCE INSTRUCTIONS DESCRIPTION This task covers: a. Removal b. Installation INITIAL SETUP Tools: Tool Kits, JTK–17LAL, TK–101/G, or TK–105/G (items 34, 35, & 36, Appendix E) Torque Wrench, 0–150 in.–lb (item 41, Appendix E) Work Station Kit, Electronic (item 38, Appendix E) Materials/Parts: Nuts, Self–Locking (item 2, Appendix F) Packing, Preformed (item 11, Appendix F) Equipment Conditions: DU bottom cover removed; if not, remove bottom cover in accordance with paragraph 3–13 Personnel Required: One MOS 35Y a. REMOVAL CAUTION ESD SENSITIVE The DU contains ESD sensitive components. Wear a protective ESD wrist strap whenever handling components. Failure to comply may result in damage to equipment. 1. Attach ESD grounding strap to wrist and ground, to ensure ESD protection. 2. Remove two self–locking nuts (1) and two washers (2) securing handle (3) to DU housing. Discard self–locking nuts. 3. Remove handle (3) and two preformed packings (4) from DU housing. Discard preformed packings. 1 2 3 4