TM9-2920-225-34 c. Cleaning. There are no special cleaning procedures needed. Refer to cleaning procedures given in para 1-3. d. Inspection and Repair. . L L FRAME 1 1. 2. 3. 4. Check that capacitor assembly ( 1), brush holder (2), and connector socket (3) are not cracked and that they have no loose leads or corroded terminals. Throw away damaged parts and get new parts. Check that brushes (4) are not cracked or oil soaked and that they have no loose leads. Throw away brushes if they are damaged. Measure distance A on brushes (4). Brush length must be at least 1/4 inch. Throw away brushes if they are worn past limit. Check that housing (5) is not cracked or warped. If housing is cracked or warped, generator is nonrepairable. GO TO FRAME 2 TA103568 2-67