TM-9-2920-225-34 HMMWV Generator Direct Support & General Support Maintenance Manual Download

Page 243 of 263

TM 9-2920-225-34 (2) 100-ampere generator. I I 1. Place DC AMMETER LOAD AND STARTER selector (1) in 150A position. 2. Set DC AMMETER FIELD AND BATTERY CHARGER selector (2) in 15A position. 3. Make sure that DC VOLTMETER RANGE selector (3) is in 50V position. 4. Make sure that DC VOLTMETER RANGE selector (2) is in RECT /GEN position. 5. Set FIELD CIRCUIT switch (5) to MANUAL position. GO TO FRAME 2 TA 103719 2-227