TM-9-2920-225-34 HMMWV Generator Direct Support & General Support Maintenance Manual Download
Page 238 of 263
TM 9-2920-225-34  c. Harness Connections.  (1) 60-ampere generator.  FRAME 1  1. Hook up test lead (1) from generator B+ terminal (2) to G+ terminal (3) of  generator binding post on test stand.  2. Hook up test lead (4) from generator ground (5) to G- terminal (6) of genera-  tor binding post on test stand.  3. Hook up test lead (7) from generator ignition lead (8) to F terminal (9) of  generator binding post on test stand.  4. Hook up test lead (10) between F-B terminal and IGN-SW terminal as shown.  END OF TASK  REGULATOR  B+ B-  STARTER  o  0  0 0  ALTERNATOR  o 0 0 I  TA 103648  2-222