TM-9-2920-225-34 HMMWV Generator Direct Support & General Support Maintenance Manual Download
Page 238 of 263
TM 9-2920-225-34 c. Harness Connections. (1) 60-ampere generator. FRAME 1 1. Hook up test lead (1) from generator B+ terminal (2) to G+ terminal (3) of generator binding post on test stand. 2. Hook up test lead (4) from generator ground (5) to G- terminal (6) of genera- tor binding post on test stand. 3. Hook up test lead (7) from generator ignition lead (8) to F terminal (9) of generator binding post on test stand. 4. Hook up test lead (10) between F-B terminal and IGN-SW terminal as shown. END OF TASK REGULATOR B+ B- STARTER o 0 0 0 ALTERNATOR o 0 0 I TA 103648 2-222