TM-9-2920-225-34 HMMWV Generator Direct Support & General Support Maintenance Manual Download

Page 210 of 263

TM 9-2920-225-34 FRAME 2 I 1. 2. 3. 4. 5. 6. 7. Check that fan (1) is not cracked or broken. If fan is damaged, generator is nonrepairable. Check that end bell (2) has no cracks, breaks or warping. If end bell is damaged, generator is nonrepairable. Check that all screws (3) are not bent or broken and that they have no damaged heads or stripped threads. If screws are damaged, get new ones. Check that spacers (4) and washers (5) are not cracked or worn. If parts are damaged, get new ones. Check that woodruff keys (6) are not bent or broken. If keys are damaged, get new ones. Check that nut (7) and washer (8) are not worn, stripped or damaged. If parts are damaged, get new ones. Check that bearing (9) is not damaged. Refer to TM 9-214. If bearing is damaged, get a new one. GO TO FRAME 3 NOTE: CHECK ONLY THOSE PARTS WHICH ARE CALLED OUT IN THIS FRAME. PARTS WITHOUT CALLOUTS ARE SHOWN ONLY FOR REFERENCE PURPOSES OR ARE CHECKED IN ANOTHER FRAME. TA 103689 2-194