TM-9-2920-225-34 HMMWV Generator Direct Support & General Support Maintenance Manual Download
Page 201 of 263
TM 9-2920-225-34 c. Inspection. FRAME 1 1. 2. 3. 4. Check that stator (1) and connector (2) have no cracks or breaks. If cracks or breaks are found, generator is nonrepairable, Check that connector (2) has no loose rims or stripped threads. If connector is damaged, generator is nonrepairable. CAUTION Do not use a battery or test lamp test. Reverse battery connection instantly. to make a continuity will burn out diodes Using multimeter, check stator (1) for continuity. Touch test probes of multimeter to pins (3, 4, and 5, and 3 and 5). Multimeter must show continuity between each set of pins. NOTE Pins (6, 7, and 8) are not tested for continuity. Make sure that they are not touching stator (1). Using multimeter, check stator (1) for open circuits. Touch one test probe of multimeter to stator housing, and the other test probe to each pin (3 through 8) on connector (2). Each check must show an open circuit. END OF TASK TA 103683 2-185