TM-9-2920-225-34 HMMWV Generator Direct Support & General Support Maintenance Manual Download
Page 191 of 263
TM 9-2920-225-34 d. Cleaning. There are no special cleaning procedures needed. Refer to cleaning procedures given in para 1-3. e. Inspection and Repair. (1) Inspection. 1. 2. 3. 4. 5. 6. 7. NOTE If rotor (1) is not within limits given in tables 2-6 and 2-7, generator is nonrepairable. Measure outside diameter of sliprings (2). Measure outside diameter of shaft at fan end bearing seat (3). Measure outside diameter of shaft at fan hub seat (4). Measure outside diameter of shaft at drive end bearing seat (5). Measure outside diameter of shaft at drive end (6). NOTE If bearing (7) is not within limits given in tables 2-6 and 2-7, get new bearing. Measure drive end bearing (7) inside diameter (8). Measure drive end bearing (7) outside diameter (9). GO TO FRAME 2 2-175