TM-9-2920-225-34 HMMWV Generator Direct Support & General Support Maintenance Manual Download
Page 184 of 263
TM 9-2920-225-34 (2) Model 5300GP. FRAME 1 NOTE Make sure that connector leads (1) do not get damaged when pressing slipring end housing (2) onto rotor shaft (3). 1. Check connector leads (1) and press slipring end housing (2) into rotor shaft ( 3). 2. Align scribe marks on slipring end housing (2) and stator (4). Put in seven screws (5) and seven lockwashers (6). GO TO FRAME 2 TA104255 I 2-168