33-13. RIGHT FRONT FLOOR PANEL REPAIR (Cont’d) TM 9-2320-387-24-2 33-78 Change 1 1. Position metal strip C (2), with arrow facing up and toward metal strip A (5), on insert panel (1). Align reference lines (4) of metal strip A (5) and C (2) and line (3) with edge of metal strip C (2). 2. Using metal strip C (2) as a template, locate, mark, and drill eight 0.187-in. (4.75-mm) diameter holes through insert panel (1). 3. Apply approximately 0.125-in. (3.175-mm) thickness of adhesive sealant to shaded surface of insert panel (1) and metal strip C (2). 4. Position metal strip C (2) on insert panel (1) and install with eight rivets (6). 5. Remove any adhesive residue and clean edges of metal strip C (2) and insert panel (1). f. Metal Strip C and Insert Panel Assembly DRILL EIGHT 0.187-IN. (4.75-MM) DIAMETER HOLES