TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 2 Download

Page 1305 of 1555

33-13. RIGHT FRONT FLOOR PANEL REPAIR (Cont’d) TM 9-2320-387-24-2 33-76 Change 1 1. Position metal strip B (1), with arrow facing up and toward metal strip A (3), on insert panel (2). Align reference lines (4) on metal strips A (3) and B (1) and line (5) with edge of metal strip B (1). 2. Using metal strip B (1) as a template, locate, mark, and drill nine 0.187-in. (4.75-mm) diameter holes through insert panel (2). 3. Apply approximately 0.125-in. (3.175-mm) thickness of adhesive sealant to shaded surface of insert panel (2) and metal strip B (1). 4. Position metal strip B (1) on insert panel (2) and install with nine rivets (6). 5. Remove any adhesive residue and clean edges of metal strip B (1) and insert panel (2). e. Metal Strip B and Insert Panel Assembly DRILL NINE 0.187-IN. (4.75-MM) DIAMETER HOLES