TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 2 Download
Page 1275 of 1555
33-12. LEFT REAR FLOOR PANEL REPAIR (Cont’d) TM 9-2320-387-24-2 33-46 Change 1 6. Cut two metal strips (1) from sheet metal, and mark centerline (2). Identify metal strips (1) as G and H. 7. Locate, mark, and drill fourteen 0.187-in. (4.75-mm) diameter holes through metal strips G and H (1). DRILL FOURTEEN 0.187-IN. (4.75-MM) DIAMETER HOLES DRILL FOURTEEN 0.187-IN. (4.75-MM) DIAMETER HOLES METRIC CONVERSION 0.60 IN. 15.24 MM 1.20 IN. 30.48 MM 1.25 IN. 31.75 MM 1.40 IN. 35.56 MM 2.50 IN. 63.50 MM 2.90 IN. 73.66 MM 3.00 IN. 76.20 MM 14.20 IN. 360.68 MM