TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 2 Download

Page 1274 of 1555

33-12. LEFT REAR FLOOR PANEL REPAIR (Cont’d) TM 9-2320-387-24-2 Change 1 33-45 4. Cut two metal strips (5) from sheet metal, and mark centerline (7), and directional arrow (6). Identify metal strips (5) as E and F. 5. Locate, mark, and drill fourteen 0.187-in. (4.75-mm) diameter holes through metal strips E and F (5). METRIC CONVERSION 0.60 IN. 15.24 MM 1.25 IN. 31.75 MM 1.40 IN. 35.56 MM 1.45 IN. 36.83 MM 2.00 IN. 50.80 MM 2.50 IN. 63.50 MM 14.20 IN. 360.68 MM DRILL FOURTEEN 0.187-IN. (4.75-MM) DIAMETER HOLES DRILL FOURTEEN 0.187-IN. (4.75-MM) DIAMETER HOLES