TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 2 Download
Page 1269 of 1555
33-12. LEFT REAR FLOOR PANEL REPAIR (Cont’d) TM 9-2320-387-24-2 33-40 Change 1 NOTE All dimensions are in inches. For metric conversion, see chart. 1. Cut insert panel (1) from sheet metal as shown, and mark six reference lines (2) and directional arrow (3) on insert panel (1). 2. Locate, mark, and drill two 0.312-in. (7.925-mm) diameter holes through insert panel (1). 3. Locate, mark, and drill a 1.000-in. (25.400-mm) diameter hole through insert panel (1). 4. Fabricate two drain holes (4) in insert panel (1). 5. Bend insert panel (1) 1.50-in. (38.10-mm). 6. Remove all burrs and round all sharp edges on insert panel (1). a. Left Rear Insert Panel Fabrication METRIC CONVERSION 1.25 IN. 31.75 MM 3.00 IN. 76.20 MM 8.00 IN. 203.20 MM 16.50 IN. 419.10 MM 30.00 IN. 762.00 MM