TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 2 Download

Page 1257 of 1555

TM 9-2320-387-24-2 33-28 Change 1 33-11. LEFT FRONT FLOOR PANEL REPAIR (Cont’d) 1. Position metal strip C (1), with arrow facing up and toward metal strip A (4), on insert panel (2). Align reference lines (3). 2. Using metal strip C (1) as a template, locate, mark, and drill seven 0.187-in. (4.75-mm) diameter holes in insert panel (2). Remove metal strip C (1). 3. Apply approximately 0.125-in. (3.175-mm) thickness of adhesive sealant to shaded surface of insert panel (2) and metal strip C (1). 4. Position metal strip C (1) on insert panel (2) and install with seven rivets (5). 5. Remove any adhesive residue and clean edges of metal strip C (1) and insert panel (2). e. Metal Strip C and Insert Panel Assembly DRILL SEVEN 0.187-IN. (4.75-MM) DIAMETER HOLES 5