METRIC CONVERSION 0.125 IN. 3.175 MM 0.18 IN. 4.57 MM 0.60 IN. 15.24 MM 0.75 IN. 19.05 MM 1.00 IN. 25.40 MM 1.40 IN. 35.56 MM 1.80 IN. 45.72 MM 1.85 IN. 46.99 MM 1.90 IN. 48.26 MM 2.00 IN. 50.80 MM 2.125 IN. 53.98 MM 2.13 IN. 54.10 MM 2.28 IN. 57.91 MM 2.50 IN. 63.50 MM 4.87 IN. 123.70 MM 5.13 IN. 130.30 MM 5.90 IN. 149.86 MM 6.00 IN. 152.40 MM 6.90 IN. 175.26 MM 7.71 IN. 195.83 MM 7.92 IN. 201.17 MM 10.80 IN. 274.32 MM 15.47 IN. 392.94 MM 25.50 IN. 647.70 MM 35.50 IN. 901.70 MM TM 9-2320-387-24-2 33-20 Change 1 33-11. LEFT FRONT FLOOR PANEL REPAIR (Cont’d) 2. Locate, mark, and drill six 0.218-in. (5.537-mm) diameter holes through insert panel (1). 3. Fabricate drain hole (2) in insert panel (1). 4. Cut and remove 0.180-in. (4.572-mm) of material from insert panel (1), remove all burrs, and round sharp edges on insert panel (1). 1. Cut metal strip (4) from sheet metal and mark two reference lines (3), centerline (5), directional arrow (6), and letter A on metal strip (4). 2. Locate, mark, and drill twenty-three 0.187-in. (4.75-mm) diameter holes in metal strip A (4). b. Metal Strips Fabrication