TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 1 Download
Page 746 of 1205
TM 9-2320-387-24-1 Change 1 4-19 FOLLOW-ON TASKS: • Install alternator cables (para. 4-8.2). • Connect battery ground cables (para. 4-68). • Lower and secure hood (TM 9-2320-387-10). 8. Install ground strap (8) on stud (9) with washers (10) and (7), lockwasher (6), and nut (5). 9. Position 3/8-in. breaker bar or, as appropriate, a 1/2-in. ratchet wrench on belt tensioner (4) and move tensioner (4) clockwise and install drivebelt (1) on power steering pump pulley (3) and alternator pulley (2). 4-8.3. 400-AMPERE DUAL VOLTAGE ALTERNATOR REPLACEMENT (Cont’d) 1 2 3 4