TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 1 Download

Page 739 of 1205

4-18.6 Change 1 7. Remove nut (6), screw (1), and cable (2) with clamp (7) from oil pan bracket (8). 8. Remove nut (3), lockwasher (4), and cable (2) from positive starter terminal (5). Discard lockwasher (4). 9. Remove nut (11), lockwasher (12), washer (13), cable (2), and clamp (9) from stud (10) on thermostat housing (14). Discard lockwasher (12). 10. Remove nut (15), washer (16), cable (2), and clamp (18) from stud (17). TM 9-2320-387-24-1 4-8.2. 400-AMPERE DUAL VOLTAGE ALTERNATOR CABLE REPLACEMENT (Cont’d)