TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 1 Download

Page 736 of 1205

FOLLOW-ON TASKS: • Connect battery ground cables (para. 4-68). • Lower and secure hood (TM 9-2320-387-10). TM 9-2320-387-24-1 Change 1 4-18.3 4-8.1. 400-AMPERE DUAL VOLTAGE REGULATOR REPLACEMENT (Cont’d) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 19 18 17 20 21 22 23 24 25