TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 1 Download

Page 731 of 1205

4-7. 200-AMPERE DUAL VOLTAGE UMBILICAL POWER CABLE REPLACEMENT (Cont'd) TM 9-2320-387-24-1 4-16 Change 1 1. Install grommet (5) on battery box (7). 2. Route umbilical power cable assembly (14) through coverplate (11) and grommet (5), and position in approximate mounting location on vehicle (10). 3. Install cover chain (17) on mounting bracket (16) with screw (19) and nut (15). 4. Install umbilical power cable assembly (14) on mounting bracket (16) with four screws (20) and nuts (4). 5. Install cover (18) on umbilical power cable assembly (14). 6. Install coverplate (11) on B-beam (6) with two washers (12), lockwashers (13), and five capscrews (3). 7. Install mounting bracket (16) on coverplate (11) with two washers (2), capscrews (1), washers (8), and nuts (9). 8. Install two cables (24) and negative power cable (23) on shunt (25) with lockwasher (22) and capscrew (21). 9. Install positive power cable (27) on buss bar (26) with washer (28), lockwasher (29), and nut (30). 10. Apply silicone compound to cable (27), coating all exposed metallic surfaces. b. Installation 5 6 7 8 9 10 12 13 3 17 18 19 20 1 2 16 15 14 4 3 ~ 11 ~